Record: Date, hour, three probe readings, turning dates, and any smell change such as sharp ammonia.
Fix three probe points: core, mid depth and edge.
Read all three at the same hour every day.
Draw the three lines on one sheet of graph paper.
Mark each turning and watch how fast heat returns.
Flag any core reading above 80 degrees the same day.